Availability: | |
---|---|
Quantity: | |
MSHP
micoe
Products Description of Spa Heater Pool Heater Air Source Swimming Pool Heat Pump:
1) R410A refrigerant, environmentally friendly.
2) Higher water temperature output to 40℃ 。
3) Titanium heat ex-changer corrosion resistance.
4) High pressure protection function.
5) Defrost automatically, intelligent and fast.
6) Smart control system MODBUS
7) Full automatically operation.
8)Low Maintainess Cost
Character & Applications
Micoe pool heat pump can realize the function of transporting low temperature heat energy to high temperature heat energy, can make large use of the heat from natural resources and waste heat resources, safe and reliable, long life, energy saving and environmental protection.
Especially suitable for indoor and outdoor standard swimming pool, recreational swimming pool, massage pool, sauna pool, to achieve constant temperature pool.
Technology Data of Spa Heater Pool Heater Air Source Swimming Pool Heat Pump:
Model No. | MSHP-025A1 | MSHP-050A1 | MSHP-075A1 | MSHP-120A1 | MSHP-170A1 | MSHP-220A1 |
Power Supply | 380V/3/50Hz | |||||
Heating Capacity at Air 27℃/24℃, Water 27℃ in, 29℃ out | ||||||
Heating Capacity(kW) | 25 | 50 | 75 | 120 | 170 | 220 |
Power Input(kW) | 4.2 | 8.4 | 12.8 | 20.1 | 28.6 | 37.6 |
COP | 5.91 | 5.95 | 5.86 | 5.98 | 5.95 | 5.85 |
Heating Capacity at Air 15℃/12℃, Water 26℃ in, 28℃ out | ||||||
Heating Capacity(kW) | 20 | 42 | 65 | 100 | 140 | 185 |
Power Input(kW) | 4.1 | 8.6 | 13.5 | 20.4 | 28.9 | 38.6 |
COP | 4.86 | 4.88 | 4.81 | 4.89 | 4.85 | 4.79 |
Cooling Capacity at Air 35℃/24℃, Water 29℃ in, 27℃ out | ||||||
Cooling Capacity(kW) | 18 | 36 | 56 | 85 | 120 | 160 |
Power Input(kW) | 5.3 | 10.5 | 16.6 | 24.6 | 35.2 | 47.6 |
EER | 3.39 | 3.42 | 3.38 | 3.45 | 3.41 | 3.36 |
Max Power Input(kW) | 6.9 | 13.2 | 20.1 | 29.1 | 48.5 | 67.2 |
Max Current(A) | 12.3 | 23.5 | 35.9 | 52.2 | 87.0 | 121.1 |
Refrigerant | R410a | |||||
Compressor Type | Scroll | |||||
Heat Exchanger | Titanium | |||||
Expansion Valve | Electronic | |||||
Air Flow Direction | Vertical | |||||
Water Flow Volume(m3/h) | 10 | 20 | 30 | 50 | 70 | 85 |
Net Dimensions(L*W*H)(mm) | 695×755×1000 | 1417×755×1000 | 1590×850×1500 | 2150×1078×2258 | ||
Working temperature range(℃) | -15~43 | |||||
Noise(dB) | ≤60 | ≤65 | ≤68 | ≤70 | ≤70 | ≤75 |
Net weight (Kg) | 120 | 250 | 460 | 760 | 900 | 1200 |
Water connection(mm) | 50 | 63 | 63 | 75 | 90 | 110 |
Our services :
Accepted Delivery Terms: FOB,CFR,CIF,EXW;
Accepted Payment Currency:USD,EUR,AUD,CNY;
Accepted Payment Type: T/T,L/C;
Language Spoken:English,Chinese,Spanish,Korean
Products Description of Spa Heater Pool Heater Air Source Swimming Pool Heat Pump:
1) R410A refrigerant, environmentally friendly.
2) Higher water temperature output to 40℃ 。
3) Titanium heat ex-changer corrosion resistance.
4) High pressure protection function.
5) Defrost automatically, intelligent and fast.
6) Smart control system MODBUS
7) Full automatically operation.
8)Low Maintainess Cost
Character & Applications
Micoe pool heat pump can realize the function of transporting low temperature heat energy to high temperature heat energy, can make large use of the heat from natural resources and waste heat resources, safe and reliable, long life, energy saving and environmental protection.
Especially suitable for indoor and outdoor standard swimming pool, recreational swimming pool, massage pool, sauna pool, to achieve constant temperature pool.
Technology Data of Spa Heater Pool Heater Air Source Swimming Pool Heat Pump:
Model No. | MSHP-025A1 | MSHP-050A1 | MSHP-075A1 | MSHP-120A1 | MSHP-170A1 | MSHP-220A1 |
Power Supply | 380V/3/50Hz | |||||
Heating Capacity at Air 27℃/24℃, Water 27℃ in, 29℃ out | ||||||
Heating Capacity(kW) | 25 | 50 | 75 | 120 | 170 | 220 |
Power Input(kW) | 4.2 | 8.4 | 12.8 | 20.1 | 28.6 | 37.6 |
COP | 5.91 | 5.95 | 5.86 | 5.98 | 5.95 | 5.85 |
Heating Capacity at Air 15℃/12℃, Water 26℃ in, 28℃ out | ||||||
Heating Capacity(kW) | 20 | 42 | 65 | 100 | 140 | 185 |
Power Input(kW) | 4.1 | 8.6 | 13.5 | 20.4 | 28.9 | 38.6 |
COP | 4.86 | 4.88 | 4.81 | 4.89 | 4.85 | 4.79 |
Cooling Capacity at Air 35℃/24℃, Water 29℃ in, 27℃ out | ||||||
Cooling Capacity(kW) | 18 | 36 | 56 | 85 | 120 | 160 |
Power Input(kW) | 5.3 | 10.5 | 16.6 | 24.6 | 35.2 | 47.6 |
EER | 3.39 | 3.42 | 3.38 | 3.45 | 3.41 | 3.36 |
Max Power Input(kW) | 6.9 | 13.2 | 20.1 | 29.1 | 48.5 | 67.2 |
Max Current(A) | 12.3 | 23.5 | 35.9 | 52.2 | 87.0 | 121.1 |
Refrigerant | R410a | |||||
Compressor Type | Scroll | |||||
Heat Exchanger | Titanium | |||||
Expansion Valve | Electronic | |||||
Air Flow Direction | Vertical | |||||
Water Flow Volume(m3/h) | 10 | 20 | 30 | 50 | 70 | 85 |
Net Dimensions(L*W*H)(mm) | 695×755×1000 | 1417×755×1000 | 1590×850×1500 | 2150×1078×2258 | ||
Working temperature range(℃) | -15~43 | |||||
Noise(dB) | ≤60 | ≤65 | ≤68 | ≤70 | ≤70 | ≤75 |
Net weight (Kg) | 120 | 250 | 460 | 760 | 900 | 1200 |
Water connection(mm) | 50 | 63 | 63 | 75 | 90 | 110 |
Our services :
Accepted Delivery Terms: FOB,CFR,CIF,EXW;
Accepted Payment Currency:USD,EUR,AUD,CNY;
Accepted Payment Type: T/T,L/C;
Language Spoken:English,Chinese,Spanish,Korean
What are the differences between inverter heat pumps and fixed frequency heat pump?
The composition configuration of the Swimming Pool Heat Pump
Micoe Lhasa Base Large Flat Plate Solar Collector Is in Place
Micoe 'Top 10 News Events' of the 20th Anniversary Awards Ceremony
Micoe/Stage III Production Base Established in Ninghai Industrial Zone