MMHP
micoe
Description of Multi-function EVI DC Inverter Heat Pump:
1. Full DC Inverter technology:With Panasonic twin rotary compressor .
2. EVI Technology:EVI technology is adopted so that unit can function well under low ambient temperature of -30 ℃ .
3. Wifi Control with Phone APP :Modern touch controller with Wifi , user friendly and intellgient.
4. Warranty:3 years on the whole system , 5 years for the compressor .
5. Low noise levelSpecial design of air system which can work in super quiet condition with low noise level of 39db.
6. Famous Brand Water Pump Built-In .
Product Data:
Air Source Heat Pump | |||||
Model | MMHP-008B1 | MMHP-012B1 | MMHP-016B1 | ||
Power Supply | 220-240V~/50Hz | 220-240V~/50Hz | 220-240V~/50Hz | ||
Heating ¹ | Capacity | KW | 2.50-8.30 | 4.20-12.20 | 5.30-16.50 |
Input Power | KW | 0.57-1.92 | 0.86-2.88 | 1.15-4.15 | |
Input Current | A | 2.53-8.52 | 3.82-12.77 | 5.10-18.41 | |
Heating ² | Capacity | KW | 2.30-7.62 | 3.85-11.20 | 4.90-15.10 |
Input Power | KW | 0.75-2.61 | 1.13-3.75 | 1.65-5.25 | |
Input Current | A | 3.32-11.58 | 5.01-16.60 | 7.32-23.30 | |
Cooling | Capacity | KW | 1.80-7.10 | 2.60-10.30 | 4.50-13.50 |
Input Power | KW | 0.61-2.43 | 0.91-3.65 | 1.45-4.85 | |
Input Current | A | 2.71-10.78 | 4.03-16.19 | 6.43-21.52 | |
SCOP (Water Temp. At 35℃) | 4.92 | 4.55 | 4.58 | ||
SCOP (Water Temp. At 55℃) | 3.37 | 3.41 | 3.39 | ||
EER (Water Temp. at 7 ℃) | 3.16 | 3.12 | 3.15 | ||
Rated Input Power | kW | 2.71 | 3.83 | 6.2 | |
Rated Input Current | A | 12 | 17 | 27.5 | |
Refrigerant Type/Charge/GWP | .../kg | R32/1.25/675 | R32/1.80/675 | R32/2.8/675 | |
CO₂ Equivalent | / | 0.84t | 1.21t | 1.89t | |
Operation Pressure(Low Side) | MPa | 1.5 | 1.5 | 1.5 | |
Operation Pressure(High Side) | MPa | 4.4 | 4.4 | 4.4 | |
Maximum Allowable Pressure | MPa | 4.4 | 4.4 | 4.4 | |
Electrical Shockproof | / | I | I | I | |
IP Class | / | IPX4 | IPX4 | IPX4 | |
Max. Outlet Water Temp. | ℃ | 60 | 60 | 60 | |
Operating Ambient Temperature | ℃ | -25~45 | -25~45 | -25~45 | |
Water Piping Connections | inch | G1" | G1" | G1-1/4 | |
Rated Water Flow | m³/h | 1.1 | 1.75 | 2.52 | |
Water Pressure Drop | kPa | 25 | 27 | 30 | |
Min/Max water pressure | MPa | 0.1/0.3 | 0.1/0.3 | 0.1/0.3 | |
Noise Level | dB(A) | 50 | 52 | 55 | |
Net Dimensions ( L×W×H ) | mm | 1000×445×850 | 1000×445×850 | 1110×480×850 | |
Net Weight | kg | 102 | 107 | 124 | |
Rated Test Conditions: Heating¹:Ambient Temp 7℃/6℃(DB/WB),Water-In/Out Temp 30℃/35℃ Heating²:Ambient Temp 7℃/6℃(DB/WB),Water-In/Out Temp 47℃/55℃ Cooling:Ambient Temp 35℃/24℃(DB/WB),Water-In/Out Temp 12℃/7℃ | |||||
Description of Multi-function EVI DC Inverter Heat Pump:
1. Full DC Inverter technology:With Panasonic twin rotary compressor .
2. EVI Technology:EVI technology is adopted so that unit can function well under low ambient temperature of -30 ℃ .
3. Wifi Control with Phone APP :Modern touch controller with Wifi , user friendly and intellgient.
4. Warranty:3 years on the whole system , 5 years for the compressor .
5. Low noise levelSpecial design of air system which can work in super quiet condition with low noise level of 39db.
6. Famous Brand Water Pump Built-In .
Product Data:
Air Source Heat Pump | |||||
Model | MMHP-008B1 | MMHP-012B1 | MMHP-016B1 | ||
Power Supply | 220-240V~/50Hz | 220-240V~/50Hz | 220-240V~/50Hz | ||
Heating ¹ | Capacity | KW | 2.50-8.30 | 4.20-12.20 | 5.30-16.50 |
Input Power | KW | 0.57-1.92 | 0.86-2.88 | 1.15-4.15 | |
Input Current | A | 2.53-8.52 | 3.82-12.77 | 5.10-18.41 | |
Heating ² | Capacity | KW | 2.30-7.62 | 3.85-11.20 | 4.90-15.10 |
Input Power | KW | 0.75-2.61 | 1.13-3.75 | 1.65-5.25 | |
Input Current | A | 3.32-11.58 | 5.01-16.60 | 7.32-23.30 | |
Cooling | Capacity | KW | 1.80-7.10 | 2.60-10.30 | 4.50-13.50 |
Input Power | KW | 0.61-2.43 | 0.91-3.65 | 1.45-4.85 | |
Input Current | A | 2.71-10.78 | 4.03-16.19 | 6.43-21.52 | |
SCOP (Water Temp. At 35℃) | 4.92 | 4.55 | 4.58 | ||
SCOP (Water Temp. At 55℃) | 3.37 | 3.41 | 3.39 | ||
EER (Water Temp. at 7 ℃) | 3.16 | 3.12 | 3.15 | ||
Rated Input Power | kW | 2.71 | 3.83 | 6.2 | |
Rated Input Current | A | 12 | 17 | 27.5 | |
Refrigerant Type/Charge/GWP | .../kg | R32/1.25/675 | R32/1.80/675 | R32/2.8/675 | |
CO₂ Equivalent | / | 0.84t | 1.21t | 1.89t | |
Operation Pressure(Low Side) | MPa | 1.5 | 1.5 | 1.5 | |
Operation Pressure(High Side) | MPa | 4.4 | 4.4 | 4.4 | |
Maximum Allowable Pressure | MPa | 4.4 | 4.4 | 4.4 | |
Electrical Shockproof | / | I | I | I | |
IP Class | / | IPX4 | IPX4 | IPX4 | |
Max. Outlet Water Temp. | ℃ | 60 | 60 | 60 | |
Operating Ambient Temperature | ℃ | -25~45 | -25~45 | -25~45 | |
Water Piping Connections | inch | G1" | G1" | G1-1/4 | |
Rated Water Flow | m³/h | 1.1 | 1.75 | 2.52 | |
Water Pressure Drop | kPa | 25 | 27 | 30 | |
Min/Max water pressure | MPa | 0.1/0.3 | 0.1/0.3 | 0.1/0.3 | |
Noise Level | dB(A) | 50 | 52 | 55 | |
Net Dimensions ( L×W×H ) | mm | 1000×445×850 | 1000×445×850 | 1110×480×850 | |
Net Weight | kg | 102 | 107 | 124 | |
Rated Test Conditions: Heating¹:Ambient Temp 7℃/6℃(DB/WB),Water-In/Out Temp 30℃/35℃ Heating²:Ambient Temp 7℃/6℃(DB/WB),Water-In/Out Temp 47℃/55℃ Cooling:Ambient Temp 35℃/24℃(DB/WB),Water-In/Out Temp 12℃/7℃ | |||||