An All-in-one heat pump is a heat pump that has three functions: Providing hot water , dehumidifying air in the swimming pool, and indoor air conditioning. It also has the function of fresh air exhaust and heat recovery.
Here is the content list:
What is the integrated dehumidification all-in-one heat pump air conditioning refrigeration function?
What is the heat recovery function of the all-in-one dehumidification heat pump?
What is an all-set dehumidification heat pump integrated heat pump air system?
The use of condensers depends on the weather conditions and the number of people in the pool. In low-temperature areas, the air does not need to be cooled in summer can not choose a condenser; in the south of the need for indoor air-conditioning cooling areas, an all-in-one heat pump is best to configure condenser, instead of air-conditioning. In summer, when the indoor air is overheated and the air conditioning and cooling function is needed, the outdoor condenser will start the cooling function. Outdoor condenser and air conditioning outdoor unit principle is the same, mainly to the excess heat out of the outdoor. Outdoor condenser, generally air-cooled radiator, like air-conditioning outdoor unit, to go to the refrigerant copper tube connection. But if the all-in-one heat pump is too far away from the mainframe, you can also use the cooling tower of the air conditioning, go to the water-cooling mode, the cold water into the mainframe refrigeration.
All-in-one dehumidification heat pump is the principle of air source heat pump, so the device also absorbs heat from the air as a source of heat (including heat from indoor pool water, which British studies have found accounts for 90% of the heat released by pool water), that is, it absorbs the heat from the indoor air, so the heat from the indoor air is not wasted (especially the heated air in winter is not wasted outside), but is absorbed by the equipment, reheat the indoor pool water and the indoor air. Fully Save Energy and operating costs, and according to the requirements in the exhaust system installed exhaust heat recovery device, so that the heat discharged to the outdoor air is almost fully recovered and reused. Thereby reducing heat loss, energy-saving, and emission reduction, and protecting the environment.
Reasonable air distribution can make indoor air temperature and humidity uniform, avoid condensation phenomena, so the design of the air duct system is crucial. All-in-one heat pump air duct organization design, the distribution of air supply can use one or more pipes, airflow direction down or direction prone to condensation walls, windows, etc. Return Air may be distributed using a pipe or branch with the return air outlet downward. Air Duct Design must ensure that there is no short circuit between supply air and return air otherwise it will exceed the high humidity layer and airbag. Fresh air outlet and vent distance can not be too close otherwise all-in-one heat pump will cause part of the ventilation directly into the fresh air system. It has been proved by many years of engineering practice that the diagonal installation of the air supply outlet and the air return outlet can make the equipment work most effectively in the indoor swimming pool. When the air duct is installed, the air supply outlet, the return air outlet, and the fresh air outlet must be installed with the air volume regulating valve. Rational selection of air volume proportion in seasonal climate change. Electric fire-proof air valves should be installed in the air supply port and connected with the fire control system. The air supply outlet, the return air outlet, the exhaust air outlet should install the muffler, reduces the noise.
MICOE Group ( stock code 603366 ) as China biggest supplier of solar water heater and hot water system, is a high-tech company which specializing in researching, manufacturing and marketing of renewable products. The business scope of the company involves solar water heater, heat pump water heater; water purifier; water tank and the heat pump-solar energy composite application etc, which can meet the different demands from industrial, commercial and residential application. With a full range of heat pumps and heat pump components, MICOE has built domestic heat pump production line, commercial heat pump production line, water tank production line, controller production line, metal cabinet production line and other industrial production lines. The production capacity and automation degree is in the leading position of heat pump industry.
If you want to learn more about the all-in-one dehumidification heat pump, read this article.
The all-in-one heat pump is a water heater that can provide the whole family with different hot water needs with large water volume, high water pressure, and constant temperature 24 hours a day, while consuming the least energy to complete the above requirements.
Here is the content list:
The working principle of the all-in-one heat pump
Features of all-in-one heat pump
Instructions for use of all-in-one heat pump
A complete all-in-one heat pump consists of 2 main parts: Manufacture the air-conditioning part and the heating hot water part. But in fact, these two parts are closely linked, inseparable, and must work at the same time. That is, while heating hot water, it cools the kitchen. In other words, while refrigerating the kitchen, it is also heating hot water.
Its internal structure is mainly composed of four core components: compressor, condenser, expansion valve, and evaporator.
The working process is as follows: the compressor compresses the returning low-pressure refrigerant and turns it into high-temperature and high-pressure gas and discharges it. The high-temperature and high-pressure refrigerant gas flow through the copper pipe wound outside
the water tank, and the heat is transferred to the water tank through the copper pipe to cool down. The down refrigerant becomes liquid under the continuous action of pressure. After passing through the expansion valve, it enters the evaporator. Because the pressure of the evaporator drops suddenly, the liquid refrigerant quickly evaporates and becomes a gaseous state, and absorbs a lot of heat. At the same time, under the action of the fan, a large amount of air flows through the outer surface of the evaporator, and the energy in the air is absorbed by the evaporator, and the temperature of the airdrops rapidly, turning into the cold air and discharged into the kitchen. Then the refrigerant that has absorbed a certain amount of energy flows back to the compressor and enters the next cycle.
1. Safety, because it is not directly heated by electric heating elements, compared with electric water heaters, it eliminates the potential safety hazards of electricity leakage; Compared with gas water heaters, there are no safety hazards such as gas leakage or carbon monoxide poisoning, so it has better safety performance.
2. Comfortable, the all-in-one heat pump is a heat storage type. The heating function is automatically activated according to the temperature in the water tank to ensure a sufficient supply of hot water for 24 hours. Therefore, there will be no problems that cannot satisfy multiple taps at the same time like a gas water heater. The problem is that the electric water heater has a small capacity and many people need to wait for a bath.
3. Save money, because its power consumption is only a quarter of that of an equivalent electric water heater, which is equivalent to using the same amount of hot water, using an all-in-one heat pump, and the electricity bill is only a quarter of the electric heating.
4. Kitchen refrigeration, is the biggest advantage, ordinary water heaters simply cannot have the function of refrigeration. If the kitchen needs additional cooling function, you need to buy a kitchen air conditioner. Because the kitchen has oily fume, it is a special environment, so the kitchen air conditioner is different from the ordinary air conditioner, and the price is much more expensive.
5. Green and environmentally friendly, the gas water heater heats hot water by burning combustible gas, and at the same time emits a large amount of carbon dioxide, sulfur dioxide, and other harmful exhaust gas. The all-in-one heat pump just transfers the heat from the surrounding air to the water, completely achieving zero emissions, and has almost no impact on the environment. It is a true environmentally friendly water heater.
6. Low-carbon fashion, as energy-saving and emission reduction, has become the trend of the times, saving energy and reducing carbon emissions is the most fashionable way of life.
Installation: The all-in-one heat pump is usually installed on the balcony of the kitchen, and the air outlet is connected with the kitchen through the air duct so that the cold air blown out can directly enter the kitchen to achieve the cooling effect. During installation, only the hot and cold water outlets are connected with the reserved hot and cold water in the house, and they can be used by connecting them. The installation is very simple.
Operation: All-in-one heat pumps mostly use microcomputer intelligent controllers, which have time setting, timing switch function, water temperature setting, ventilation setting, overheating protection, and other intelligent control functions. However, most of the functions have been set by the manufacturer at the factory. Just use the default values. Basically, you only need to set the temperature you need (usually set at 45-50 degrees) and you can use it.
It is the responsibility of each manufacturer to produce an industrial all-in-one heat pump that meets the standards, so as to ensure the safety of the use of all-in-one heat pumps and the healthy development of the all-in-one heat pump market. MICOE many tests on all-in-one heat pumps before they leave the factory, and the quality qualification rate is guaranteed. If you are in the all-in-one heat pump business, you can consider our cost-effective products.
A heat pump is an energy-saving device that uses high-level energy to flow heat from a low-level heat source to a high-level heat source. As the low-level heat source of the heat pump, the air is inexhaustible and inexhaustible. It is available everywhere and can be obtained free of charge. Moreover, the installation and use of air source heat pumps are relatively convenient. Air source heat pumps usually use all-in-one heat pumps This kind of device is very common in large shower rooms, hotels, etc. Do you know the advantages of air heat source pumps?
Here is the content list:
What is the difference between air source heat pump water heater (heater) unit and it?
What are the advantages of air source heat pump hot water (heater) units compared with solar water heaters?
Is there any other use for the air source heat pump hot water (heater) unit besides the hot water for bathing?
Air source heat pump water heater (heater) units and solar water heaters are both devices that use natural and environmentally friendly energy to generate hot water, but they have essential differences. The air source heat pump water heater (heater) unit uses air heat as its energy source, but the way it obtains energy is active, so it is not affected by cloudy, rainy, days and nights. The way solar water heaters obtain energy is passive. It relies on direct sunlight to achieve better results. Therefore, hot water can only be produced on sunny days. Other times must rely on traditional heating methods such as electric heating assist; diesel stove assists; Gas stove auxiliary; air source heat pump water heater (heater) unit auxiliary, etc. This requires the use of an all-in-one heat pump.
Air source heat pump water heater (heater) units can save 65-80% on average, and electric solar water heaters can save 40-65% on average, and can only reach 70℅ under special circumstances. Low investment: Taking electricity-saving 65℅ as the standard, the investment of air source heat pump water heater (heater) unit is only about 70 about that of the electric solar water heater. Strong adaptability: The air source heat pump water heater (heater) unit is almost unaffected by the weather. It produces hot water around the clock, 24 hours a day, around the clock. However, solar water heaters can only be used on sunny days and used in the afternoon and evening. Other weather and morning water in other weather require other energy. In many areas of the country, the working hours of electrical auxiliary equipment for solar water heaters exceed 40 minutes. The storage tank is small: the storage tank of the solar water heater should be configured according to the maximum hot water supply throughout the day, and the all-in-one heat pump water heater (heater) unit can produce hot water at any time, and the storage tank is configured only for the maximum hot water supply 50% of it. About 70℅ can meet the requirements. Small footprint: solar water heaters usually occupy the entire floor area, and the floor area is not enough to accommodate users on the 9th floor or more. The all-in-one heat pump (heater) unit system used by the air source heat pump water heater only needs 1/9 of the area occupied by the solar water heater (heater) unit.
Except for domestic hot water, it can be used wherever hot water is needed. Such as saunas, swimming pools, industrial enterprises, agricultural breeding, etc., in such systems with lower temperature requirements, the energy efficiency ratio of the air heat pump water heater (heater) unit can be as high as 5-6, which is more energy-efficient.
It is the responsibility of each manufacturer to produce an air source heat pump that meets the standards, so as to ensure the safety of the electricity supply. MICOE conducts many tests on durable air source heat pumps before they leave the factory, and the quality qualification rate is guaranteed. If you are in the air source heat pump business, you can consider our cost-effective products.
Flat plate solar water heater invention has received a survey after the end of the study period. The primary scope is the same even under uncertainty management and relies on solar hot water heater system allowance. The flat plate solar water heater invention is not perfectly comparable with solar hot water heater system. However it does not include a role for borrowing allowances from future years nor for offsets because of the solar energy nature. Furthermore, although flat plate solar water heater invention generally includes at least a limited role for the auctioning, it provides a price discovery mechanism. There are also some advantages of solar hot water heater system among other benefits even in the lowest bound of expected prices. In fact flat plate solar water heater invention is established during trading preparation at large. And the prices have entered and surpassed the expected price range primarily and that can be attributed to uncertainty. At the same time, the advent of flat plate solar water heater invention and the transition to solar hot water heater system is reasonable to believe that expected prices will be on the increase. Further overestimated observed prices can be expected in advance and the phase would be superseded. Therefore flat plate solar water heater invention includes an expanded set of states with a advanced baseline level.
Meanwhile, solar hot water heater system allowance banking played a vital role in the flat plate solar water heater invention despite restrictions designed to minimize the risks during a hot summer. In fact, solar hot water heater system banked allowances can be accounted for more than twenty percent of allowances after the first year and the emissions never exceeded the rate in two years. This inconsistently observed flat plate solar water heater invention can provide insight into the interpretation of experimental manipulations. Here, residential consumers’ electricity use can be studied and these solar hot water heater system consumers will record their participation in a study of household solar hot water heater system use. The solution is contained in a custom designed vessel that is positioned at the focus of the solar hot water heater system reflector. The steam can be generated within flat plate solar water heater invention and is channeled into the storage module. Under typical operation, the solar hot water heater system temperature is maintained at one hundred and thirty degrees for five minutes. And the duration of time required for a standard cycle is no more than six minutes, which can be monitored at the output of the generation module. What is more, the solar hot water heater system solution temperature is expected to reach the slight thermal point in the end.