Swimming pool heat pump cost more than gas pool heaters, but they typically have much lower annual operating costs because of their higher efficiencies. With proper maintenance, a swimming pool heat pump typically lasts longer than gas pool heaters. Therefore, you'll save more money in the long run.
Here is the content list:
How They Work?
Selecting a Heat Pump Pool Heater
Determining Heat Pump Swimming Pool Heater Efficiency
swimming pool heat pumps use electricity to capture heat and move it from one place to another. They don't generate heat.
As the swimming pool heat pump circulates the swimming pool's water, the water drawn from the pool passes through a filter and the swimming pool heat pump heater. The swimming pool heat pump heater has a fan that draws in the outside air and directs it over the evaporator coil. Liquid refrigerant within the evaporator coil absorbs the heat from the outside air and becomes a gas. The warm gas in the coil then passes through the compressor. The compressor increases the heat, creating a very hot gas that then passes through the condenser. The condenser transfers the heat from the hot gas to the cooler pool water circulating through the heater. The heated water then returns to the pool. The hot gas, as it flows through the condenser coil, returns to liquid form and back to the evaporator, where the whole process begins again.
Higher efficiency swimming pool heat pumps usually use scroll compressors versus the reciprocal compressors of standard units.
Sizing a swimming pool heat pump pool heater involves many factors. A heater is sized according to the surface area of the pool and the difference between the pool and the average air temperatures. Other factors also affect the heating load for outdoor pools, such as wind exposure, humidity levels, and cool night temperatures. Therefore, pools located in areas with higher average wind speeds at the pool surface, lower humidity, and cool nights will require a larger heater.
swimming pool heat pump pool heaters are rated by Btu output and horsepower (hp). Standard sizes include 3.5 hp/75,000 Btu, 5 hp/100,000 Btu, and 6 hp/125,000 Btu.
The energy efficiency of swimming pool heat pump swimming pool heaters is measured by the coefficient of performance (COP). The higher the COP number, the more efficient. However, there is no standard test for measuring the COP. Therefore, you really can't compare the COPs of different models unless you know that the manufacturers used the same test for each model. For example, the same swimming pool heat pump will operate at a higher COP when the outside air temperature is higher.
Typically, manufacturers measure the COP by testing a swimming pool heat pump pool heater with an outdoor temperature of 80ºF and pool temperature of 80ºF. COPs usually range from 3.0 to 7.0, which converts to an efficiency of 300%–700%. This means that for every unit of electricity it takes to runs the compressor, you get 3–7 units of heat out of the swimming pool heat pump.
MICOE has developed a variety of different swimming pool heat pumps. If you are in the swimming pool heat pump business, you can consider using our cost-effective products.
If you have a pool in your home, unless you only use it in the summer, you will need a swimming pool heat pump. A Swimming pool heat pump is a part of all in one heat pump. Is it worth it? Or how to choose the best way to get the most out of your hot pool pump. If you're interested, here are some details.
Here is the content list:
How does the swimming pool heat pump work?
How do determine the efficiency of the swimming pool heat pump?
How to install and maintain the swimming pool heat pump?
The Swimming pool heat pump uses electricity to capture heat and move it from one place to another. They don't generate heat. As the pool pump circulates the swimming pool's water, the water drawn from the pool passes through a filter and the swimming pool heat pumps. The swimming pool heat pump has a fan that draws in the outside air and directs it over the evaporator coil. Liquid refrigerant within the evaporator coil absorbs the heat from the outside air and becomes a gas. The warm gas in the coil then passes through the compressor. The compressor increases the heat, creating a very hot gas that then passes through the condenser. The condenser transfers the heat from the hot gas to the cooler pool water circulating through the heater. The heated water then returns to the pool. The hot gas, as it flows through the condenser coil, returns to liquid form and back to the evaporator, where the whole process begins again.
Higher efficiency swimming pool heat pumps usually use scroll compressors versus the reciprocal compressors of standard units. Swimming pool heat pumps work efficiently as long as the outside temperature remains above the 45ºF–50ºF range. The cooler the outside air they draw in, the more energy they use. However, since most people use outdoor swimming pools during warm and mild weather, this usually isn't an issue.
The energy efficiency of the swimming pool heat pump is measured by a coefficient of performance (COP). The higher the COP number, the more efficient. However, there is no standard test for measuring the COP. Therefore, you really can't compare the COPs of different models unless you know that the manufacturers used the same test for each model. For example, the same heat pump will operate at a higher COP when the outside air temperature is higher.
Typically, manufacturers measure the COP by testing a swimming pool heat pump with an outdoor temperature of 80ºF and pool temperature of 80ºF. COPs usually range from 3.0 to 7.0, which converts to an efficiency of 300%–700%. This means that for every unit of electricity it takes to runs the compressor, you get 3–7 units of heat out of the heat pump.
Since it is a part of all-in-one heat pump, proper installation and maintenance of your swimming pool heat pump can optimize its efficiency. It's best to have a qualified pool professional install the heater, especially the electric hook-up, and perform complicated maintenance or repair tasks. Read your owner's manual for a maintenance schedule and/or recommendations. You'll probably need to tune up your pool heater annually. Because a swimming pool heat pumps many moving and electrical parts, it will probably require periodic service by an air conditioning technician. With proper installation and maintenance, swimming pool heat pumps can last 10 or more years. Use it combines with an all-in-one heat pump, keep all parts of your home warm.
The pool hot water pump will help you increase the use of your pool except in the summer, especially if you enjoy swimming. And it is a very interesting thing that, enjoy the hot gas from the pool in the winter. If you are in the swimming pool heat pumps business, you can consider our cost-effective products.
The market share ofair source heat pumps is increasing. However, because it is a new type of heating equipment, many consumers are not clear about the installation precautions, which leads to the failure of the effect or various problems. Today, the main problem is to introduce the installation of an air source heat pump system and some precautions, so that everyone makes fewer mistakes.
Here is the content list:
Installation Steps
Water pipe connection
Precautions
This article focuses on analyzing the installation precautions of the home machine. By looking up relevant information, we can see that the installation of the air source heat pump heating system can be roughly divided into the following steps:
1. Before installing the host, it is necessary to survey the installation site, select and determine the installation location of the host.
2. Make the foundation of the host equipment. If the installation location is determined to be on the ground, cement can be used. The thickness of the cement is about 15cm~20cm.
3. Place the main engine and adjust the position of the unit to ensure the stable placement of the main engine.
4. The connection to the water system is mainly the connection of the water pump, valve body, filter, and other components between the host and the water tank.
5. Connect the circuit system, mainly to connect the power cord, water pump, solenoid valve, water temperature sensor, pressure switch, etc. according to the wiring diagram requirements.
6. Waterway pressure test, check whether there is water leakage in the pipeline connection.
7. Test the operation of the machine to check various parameters of the system.
8. Pipe heat preservation, such as using rubber and plastic heat preservation materials to heat the waterway system.
There are also some differences in the diameter of the water pipes of different types of air source heat pumps. When installing the water pipes of the air source heat pump, you need to pay attention to selecting the appropriate water pipes according to the specific model. Then connect the water pipe with other accessories and valves of the heat pump. When installing, you need to pay special attention not to let other debris enter the pipeline system. When connecting the water pipe, you can use a pipe clamp to operate, so that the water pipe can be firmly fixed.
Mastering the installation steps only masters the most basic installation knowledge. What really determines the quality of the installation is the many installation details. Every step of the installation has "rules" to be followed, which also requires the installer to master it firmly. There are many "rules" for the installation of air-source heat pump hosts. If the installer understands it, it will be of great benefit to improving the quality of the installation.
1. The survey work before installation is necessary. It is very necessary to survey the installation site before installing the host.
2. The host has high requirements for the installation space environment, and installation at different locations has different requirements. The air source heat pump host can be installed on the ground, on the roof, or on the wall. If it is installed on the ground, or on a wall, in order to ensure that the heat absorption and heat dissipation of the heat exchanger of the host is not hindered, the distance between the host and the surrounding walls or other obstructions should not be too small. In addition, the equipment foundation should be well prepared; The equipment should be installed on the ground, Use expansion bolts to fix it; If it is installed on the roof, the load-bearing capacity of the roof must be considered. The roof that does not meet the load-bearing requirements is strictly not allowed to be installed. If it can be installed on the roof, pay attention to the direction of the air source heat pump. The wind direction is best to install downwind so that the heat exchange effect of the host will be better.
3. It is very important to lay a good "foundation". The foundation of the equipment must be firm and strong. On this basis, the host must be placed and adjusted smoothly, ensure that it is installed upright, and fixed with expansion bolts.
4. Take measures such as rain and snow protection for the equipment. In the actual installation, it is also necessary to consider the drainage of the host equipment, rain and snow protection, lightning protection, maintenance space, and other issues. If these details are not considered in place, they will directly affect the air. The heating effect and service life of the source heat pump heating system.
It is the responsibility of each manufacturer to produce an industrial air source heat pump that meets the standards, so as to ensure the safety of the use of air-source heat pump and the healthy development of the air source heat pump market. MICOE many tests on air-source heat pumps before they leave the factory, and the quality qualification rate is guaranteed. If you are in the air source heat pump business, you can consider our cost-effective products.
From authoritative attestation to market application, Micoe air source heat pump withstand the test of comprehensive and strict, Micoe will be based on the two large air source heat pump production bases, the accumulation of technological advantages, continue to lead the industry development of high quality, keep up with the development of The Times theme, boost national "double carbon" strategic goal, to "clean world, better life" the mission of unremitting struggle, Focus on the future.
Hefei general machinery product certification co., LTD. (GC) abbreviations is registered by the administrative department for industry and commerce, the national certification and accreditation supervision and administration commission (CNCA) approval of the China's conformity assessment (CNAS) national approval committee, with independent legal status of third-party certification body, established in 2000. GC certification center can carry out including China energy-saving product certification, CCC certification, China RoHS certification, characteristic certification, green building materials product classification certification and other professional certification.
Set simulation environment parameters
This qualification marks that Micoe Air aSource Heat Pump 250kW comprehensive performance Laboratory has the ability to simulate and test all urban environmental climates in China. For Micoe air source heat pump research and development level and product quality to provide a strong technical support, help to win the trust of government departments, all walks of life, enhance their market competitiveness.
Laboratory simulation of blizzard conditions - detect frost formation
Micoe Air Source Heat Pump 250kW Comprehensive performance laboratory includes 30HP and 60HP two specifications laboratory, in strict accordance with the national standard for 3-30HP air source heat pump unit and 3-60HP air source heat pump unit, water source heat pump unit, chiller testing and calibration. The 30HP laboratory has additional explosion-proof laboratory function, which can carry out combustible refrigerant unit test, and the 60HP laboratory has noise laboratory function, and the background noise can be at least 40 decibels below. The laboratory has been built for many years. With rich research experience and advanced technical capabilities, it possesses technical advantages such as cold source cluster regulation, complex environment artificial simulation, multi-cooling domain variable capacity cooling, and dynamic simulation of air conditioning load, which reflects the strong comprehensive competitiveness of Micoe.
Micoe North Air Source Heat Pump Production Base
As a comprehensive service provider of low-carbon and clean energy, Micoe has always been committed to breaking through the ultra-low temperature barrier with technological innovation and promoting the development of the industry with high-quality products. Micoe aijia 2 series air energy cooling and heating machine, under the working condition of -12℃, the comprehensive energy efficiency of heating reaches 3.26, exceeding the 3.2 requirements of the national first level energy efficiency, COPh≥2.65, nominal heat 20kW; The machine adopts EVI air jet enthalpy increasing technology to increase refrigerant circulation by 20% and realize quasi-two-stage compression to ensure that the machine can operate effectively at -35℃. At the same time, the machine has three-minute intelligent defrosting technology, which reduces energy consumption and ensures the comprehensive heating effect of the unit in the cold environment. This technology also won the first prize of scientific and technological invention of China Refrigeration Society in 2021.
Micoe Shunde Air Source Heat Pump Production Base
From authoritative certification to market application, Micoe Air Source Heat Pump has withstood the comprehensive and strict test. Relying on the two major air energy production bases in the North and south, Micoe will continue to accumulate technological advantages, continue to lead the high-quality development of the industry, conform to the development theme of The Times, and help achieve the national "dual carbon" strategic goal. To "clean the world, better life" mission unremitting struggle, committed to the future.