MMHP
micoe
Products Description of Industrial Geothermal 18kw Space Heating Heat Pump:
1) R410A refrigerant, environmentally friendly.
2) Higher water temperature output up to 55 ℃.
3) Adopt DC inverter technology with high efficiency.
4) High pressure protection function.
5) Defrost automatically, intelligent and fast.
6) With MODBUS communication.
7) Adapt intelligent controller, full automatically operation.
8) Operation ambient temperature can be -30 ℃ .
9) Through different installation, the system can be used for cooling or heating.
Product Paramenters of Industrial Geothermal 18kw Space Heating Heat Pump
Model No. | MMHP-012A1 | MMHP-016A1 | MMHP-018A1 | MMHP-024A1 | MMHP-028A1 | MMHP-031A1 | |
Power supply | 220V-240V/1/50Hz | 220V-240V/1/50Hz | 220V-240V/1/50Hz | 380V/1/50Hz | 380V/1/50Hz | 380V/1/50Hz | |
Heating Capacity at Air 7℃, Water 30℃ in, 35℃ out | |||||||
Heating Capacity(kW) | 12(3.2-12.8) | 16(3.5-15.9) | 18(5.2-20.5) | 24(5-24.5) | 28(6-28.5) | 31(6-31.5) | |
Power Input(kW) | 2.6 | 3.63 | 3.81 | 5.42(1.5-5.57) | 6.44(2.5-6.63) | 7.38(2.5-7.5) | |
COP | 4.62 | 4.41 | 4.72 | 4.42 | 4.35 | 4.2 | |
Heating Capacity at Air 7℃, Water 50℃ in, 55℃ out | |||||||
Heating Capacity(kW) | 10(3.1-10.9) | 12(3-13.5) | 15(4.6-18.5) | 26(5-26.5) | 27(6-27.5) | 29(6-29.5) | |
Power Input(kW) | 2.82 | 3.29 | 4.08 | 8.81(2.2-8.86) | 9.23(2.8-9.48) | 10.3(2.8-10.5) | |
COP | 3.54 | 3.64 | 3.68 | 2.95 | 2.93 | 2.81 | |
Cooling Capacity at Air 35℃, Water 12℃ in, 7℃ out | |||||||
Cooling Capacity(kW) | 8(2.6-9.1) | 12(2.8-13) | 14(4.2-16.8) | 18(5-18.5) | 20(6-20.5) | 22.5(6-23) | |
Power Input(kW) | 2.25 | 3.31 | 3.87 | 6.1(2.1-6.25) | 7.02(2.6-7.32) | 8.65(2.6-9.02) | |
EER | 3.56 | 3.62 | 3.62 | 2.95 | 2.85 | 2.6 | |
Max Power Input(kW) | 5.3 | 6.35 | 6.8 | 11.5 | 12.8 | 12.8 | |
Max Current(A) | 22 | 29 | 32 | 20 | 26 | 26 | |
Refrigerant | R410a | R410a | R410a | R410a | R410a | R410a | |
Net Weight(kg) | 75 | 147 | 147 | 160 | 200 | 200 | |
Dimensions(L*W*H)(mm) | 1005*375*800 | 1077*377*1460 | 1077*377*1460 | 1127*427*1560 | 1127*427*1560 | 1127*427*1560 | |
Compressor | GMCC | Panosonic | Panosonic | Panosonic | Panosonic | Panosonic | |
Heat exchanger type | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger |
what services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW;
Accepted Payment Currency:USD,EUR,AUD,CNY;
Accepted Payment Type: T/T,L/C;
Language Spoken:English,Chinese,Spanish,Korean
Products Description of Industrial Geothermal 18kw Space Heating Heat Pump:
1) R410A refrigerant, environmentally friendly.
2) Higher water temperature output up to 55 ℃.
3) Adopt DC inverter technology with high efficiency.
4) High pressure protection function.
5) Defrost automatically, intelligent and fast.
6) With MODBUS communication.
7) Adapt intelligent controller, full automatically operation.
8) Operation ambient temperature can be -30 ℃ .
9) Through different installation, the system can be used for cooling or heating.
Product Paramenters of Industrial Geothermal 18kw Space Heating Heat Pump
Model No. | MMHP-012A1 | MMHP-016A1 | MMHP-018A1 | MMHP-024A1 | MMHP-028A1 | MMHP-031A1 | |
Power supply | 220V-240V/1/50Hz | 220V-240V/1/50Hz | 220V-240V/1/50Hz | 380V/1/50Hz | 380V/1/50Hz | 380V/1/50Hz | |
Heating Capacity at Air 7℃, Water 30℃ in, 35℃ out | |||||||
Heating Capacity(kW) | 12(3.2-12.8) | 16(3.5-15.9) | 18(5.2-20.5) | 24(5-24.5) | 28(6-28.5) | 31(6-31.5) | |
Power Input(kW) | 2.6 | 3.63 | 3.81 | 5.42(1.5-5.57) | 6.44(2.5-6.63) | 7.38(2.5-7.5) | |
COP | 4.62 | 4.41 | 4.72 | 4.42 | 4.35 | 4.2 | |
Heating Capacity at Air 7℃, Water 50℃ in, 55℃ out | |||||||
Heating Capacity(kW) | 10(3.1-10.9) | 12(3-13.5) | 15(4.6-18.5) | 26(5-26.5) | 27(6-27.5) | 29(6-29.5) | |
Power Input(kW) | 2.82 | 3.29 | 4.08 | 8.81(2.2-8.86) | 9.23(2.8-9.48) | 10.3(2.8-10.5) | |
COP | 3.54 | 3.64 | 3.68 | 2.95 | 2.93 | 2.81 | |
Cooling Capacity at Air 35℃, Water 12℃ in, 7℃ out | |||||||
Cooling Capacity(kW) | 8(2.6-9.1) | 12(2.8-13) | 14(4.2-16.8) | 18(5-18.5) | 20(6-20.5) | 22.5(6-23) | |
Power Input(kW) | 2.25 | 3.31 | 3.87 | 6.1(2.1-6.25) | 7.02(2.6-7.32) | 8.65(2.6-9.02) | |
EER | 3.56 | 3.62 | 3.62 | 2.95 | 2.85 | 2.6 | |
Max Power Input(kW) | 5.3 | 6.35 | 6.8 | 11.5 | 12.8 | 12.8 | |
Max Current(A) | 22 | 29 | 32 | 20 | 26 | 26 | |
Refrigerant | R410a | R410a | R410a | R410a | R410a | R410a | |
Net Weight(kg) | 75 | 147 | 147 | 160 | 200 | 200 | |
Dimensions(L*W*H)(mm) | 1005*375*800 | 1077*377*1460 | 1077*377*1460 | 1127*427*1560 | 1127*427*1560 | 1127*427*1560 | |
Compressor | GMCC | Panosonic | Panosonic | Panosonic | Panosonic | Panosonic | |
Heat exchanger type | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger |
what services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW;
Accepted Payment Currency:USD,EUR,AUD,CNY;
Accepted Payment Type: T/T,L/C;
Language Spoken:English,Chinese,Spanish,Korean
Micoe has set up another example of clean heating in high altitude, extremely cold areas.
Micoe -40 ℃ Heat Pump ultra-low Temperature Laboratory was Authorized by Hefei General Institute
Micoe did his best to assist in the battle of epidemic prevention and control!
What conditions should a hot water heat pump have in its application?
What are the differences between inverter heat pumps and fixed frequency heat pump?
Micoe Xi 'an Yuandian Mahogany Expo City Clean energy Project